Wellington Solar Farm
Involvement
Lucas Redrup was contracted to complete several detailed design packages including 60%, 90% & IFC design levels for this project. This included DC Electrical Engineering, Mechanical Interface Work, Field Control Systems Engineering and general details for interface work with MV Engineers and Civil Engineers.
For this project, it is important to acknowledge that this project was designed under the strict guidance of an Ontario based Electrical P.Eng. Although all products listed were designed and drafted by Lucas Redrup, this would not have been possible without the guidance of the Engineer of Record at the time.
Equipment & Rough Quantities
500 kWAC & 600 kWDC
2,000 x Solar Modules
167 x Fixed Tilt Racking Tables
21 x String Inverters
1 x MV transformer
Products Offered
DC Electrical & Mechanical Engineering - General Package
DC Electrical Engineering - Schematics Package
DC Electrical Engineering - Trenching Design Package
DC Electrical Engineering - Module String Design Package
Mechanical Engineering - Basic Visual Impact Design Package