Wellington Solar Farm


Involvement

Lucas Redrup was contracted to complete several detailed design packages including 60%, 90% & IFC design levels for this project. This included DC Electrical Engineering, Mechanical Interface Work, Field Control Systems Engineering and general details for interface work with MV Engineers and Civil Engineers.

For this project, it is important to acknowledge that this project was designed under the strict guidance of an Ontario based Electrical P.Eng. Although all products listed were designed and drafted by Lucas Redrup, this would not have been possible without the guidance of the Engineer of Record at the time.

 Equipment & Rough Quantities

  • 500 kWAC & 600 kWDC

  • 2,000 x Solar Modules

  • 167 x Fixed Tilt Racking Tables

  • 21 x String Inverters

  • 1 x MV transformer

Products Offered

  • DC Electrical & Mechanical Engineering - General Package

  • DC Electrical Engineering - Schematics Package

  • DC Electrical Engineering - Trenching Design Package

  • DC Electrical Engineering - Module String Design Package

  • Mechanical Engineering - Basic Visual Impact Design Package


Previous
Previous

Leblanc Solar Farm

Next
Next

Hopkins Solar Farm